Page view 28
Australian Monitor Service Bulletin
AMC+ Mixer and Booster Amplifiers
Mains Fuses
20 February 2012
Page 1 of 1
Applicable Models
This bulletin applies to AMC+30, AMC+60, AMC+120 and
AMC+250 Mixer Amplifiers and the AMC+120P,
AMC+1202P and AMC+250P Booster Amplifiers manufactured prior to 2012.
Known Issue
The AMC+ range of mixer amplifiers and AMC+ booster
amplifier have experienced a higher than acceptable
incidences of mains fuse failures at turn on.
Details
AMC+ products manufactured prior to 2012 are fitted with inferior Chinese fuses.
Solution
The problem can easily be rectified by placing the existing mains fuse with name brand quality fuses available
from Element14 as follows:
115V Operation
(North America)
230V Operation
(Australia/Europe)
Model Fuse Rating Element14 Fuse Rating Element 14
AMC+30 T1A 1123115 T500mA 1123121
AMC+60 T3.15A 1123119 T1.6A 1123113
AMC+120
AMC+120P
T4A 1123120 T2A 1123118
AMC+250
AMC+250P
AMC+1202P
T8A 1123125 T4A 1123120
All fuses are Cooper Bussman 250VAC rated, slow-blow ceramic HRC type M205 cartridge.
All future production models will be fitted with these fuses.
Procedure
1. Remove the mains lead from the amplifier.
2
. Remove the fuse holder drawer that is part of the IEC mains input socket.
3. Remove the two existing fuses (one of these is a spare fuse).
4. Install two M205 size fuses as per the operating voltage above.
5. Reinstall the drawer.
Page view 28