COM 1 2 3 4
TONE MODULE
OHM
DIRECT OUT
C
C
100
LINE
4
70
CLASS 2 WIRING
230 V. FUSE T2AH 250V
AMC+ 120
115 V. FUSE T4AH 250V
Audio Amplifier
Model: AMC+120
Rated Value:
115V~60Hz 460W
230V~ 50Hz 460W
Manufacture Date:
Made In China
CERTIFIED TO
CAN/CSA STD.C22.2
No.60065
CONFORMS TO
ANSI/UL SYD.60065
This terminal is hazardous live and that external wiring connected
to these terminals requires installation by an instructed person.
5
1
CH 1–4
Each channel input section has two inputs: XLR input – This
is a balanced microphone input. It has an input sensitivity of
1mV. RCA input – This is an unbalanced line level input.
It has an input sensitivity of 150mV. The two RCA sockets
are summed to mono internally.
2
REC Output
The REC output is on unbalanced RCA connectors. The output
level is 150mV into 10kohm at rated output. The output is
dual mono.
The REC output is not affected by the MASTER volume control
or the BASS and TREBLE controls.
The REC output does not receive the tone signal if the
optional tone generator module is installed.
3
Line Output
The LINE output is on a balanced XLR connector. The output
level is 0.775V into 1k at rated output.
Note: When wiring the LINE output as unbalanced, Pin2
should be wired as hot and Pin1 should be wired as ground/
shield. Do not wire Pin3.
4
Direct Out
Speaker connections are provided on screw terminals. 4 ohm
low impedance, 70V and 100V line outputs are provided.
5
Mains Voltage Selector
The operating voltage of the amplifier is user selectable
between for 115V or 230V operation via a slide switch
located above the AC mains inlet. This switch should be set to
match the AC voltage of your country.
Failure to set the Mains Voltage Selector correctly prior
to use will result in catastrophic failure.
Minimum Impedance AMC
+
30 AMC
+
60 AMC
+
120 AMC
+
250
Distributed Line Output
70V 166ohm 83ohm 41ohm 20ohm
100V 333ohm 166ohm 83ohm 40ohm
Low Impedance Output
4ohm 4ohm 4ohm 4ohm
Note: Only connect one output – either Distributed Line or Low Impedance per channel.
Do not connect LowZ and 70/100V at the same time.
The output strip comes fitted with a touch-proof cover held in place by two M3 machine screws
with flat and spring washers.
6
IEC Mains Input Socket
This is a standard IEC 3 pin socket. It accepts a standard IEC mains cable, provided. The fuse
draw at 5 contains the mains fuse and a spare. The mains fuse is a time lag (slow blow)
HRC 20mm x 5mm ceramic type fuse.
The ratings are: AMC
+
30 AMC
+
60 AMC
+
120 AMC
+
250
230V operation 0.5A 1.6A 2A 4A
115V operation 1A 3.15A 4A 8A
Always replace the fuse with one of the same value and type.
Always disconnect power to the amplifier before replacing fuses.
7
(Optional) Tone Module
These terminals are for use with an optional tone module (not supplied). Use Australian Monitor
ATC5488 module.
8
Phantom Power
12V phantom power is available for condenser or electret microphones on the XLR input when
this switch is pushed in.
6
8
1234 7
PAGE 5AMC
+
SERIES INSTALLATION AND OPERATION MANUAL
REAR PANEL
Page view 4